Short answer
‘Fuse box’ and ‘consumer unit’ describe the same job: the board that splits your supply into circuits and protects them. The difference is the technology. Old fuse boxes use fuses that melt; modern consumer units use resettable circuit breakers plus RCD protection against electric shock, in a non-combustible enclosure. An old fuse box isn’t automatically illegal, but it offers less protection.
Same job, different technology
Every home has a board where the incoming supply is divided into separate circuits — lights, sockets, cooker, shower and so on. People call it the fuse box, fuse board, distribution board or consumer unit. Electricians tend to say ‘consumer unit’ for modern domestic boards, but the purpose has always been the same: to disconnect a circuit if something goes wrong.
What an old fuse box contains
Older boards use rewirable fuses — a ceramic carrier with a length of fuse wire — or cartridge fuses. When too much current flows, the wire melts and breaks the circuit. They protect cables from overload but are slower than modern devices, and rewirable fuses can be repaired with the wrong wire, which removes the protection altogether.
Most importantly, older fuse boxes usually have no residual current device (RCD). An RCD detects current leaking to earth — for example through a person touching a live part — and disconnects in a fraction of a second. That shock protection is the biggest single difference between old and new boards.
What a modern consumer unit contains
- MCBs (miniature circuit breakers) — switch off on overload or short circuit and can be reset.
- RCDs — protect groups of circuits against earth leakage and electric shock.
- RCBOs — combine an MCB and RCD for a single circuit, so one fault doesn’t switch off several circuits.
- Surge protection (SPD) — where appropriate, protects against transient overvoltages.
- A non-combustible enclosure — domestic consumer units have been required to be metal or equivalent since a 2016 amendment to the wiring regulations.
Do I have to replace my old fuse box?
Not automatically. There is no law that says a homeowner must replace a fuse box simply because of its age. However, an inspection may record the lack of RCD protection and other issues with codes that need action, particularly in rented homes. If the board is damaged, overheating or the wiring behind it is deteriorating, replacement is usually recommended.
A new consumer unit can only be fitted safely if the circuits it supplies are in reasonable condition, because RCDs will trip on existing faults. That is why the electrician tests circuits first and may find work that needs doing before or alongside the upgrade. See our consumer unit replacement cost guide for what that involves.
Signs your board needs attention
- Rewirable fuses with wire carriers, or a wooden or plastic-backed board.
- No RCD test button anywhere on the board.
- Scorch marks, a burning smell, crackling or a board that feels warm.
- Fuses that blow or breakers that trip repeatedly.
- A board crammed with add-on devices from later extensions.
Replacing a board
Replacing a consumer unit is notifiable under Part P of the Building Regulations in England, so it should be done by a registered electrician who will test the installation, issue an Electrical Installation Certificate and notify Building Control through their scheme. David J Farrar & Associates are Part P, NAPIT and NICEIC registered and provide free quotations across south-east London and North Kent.
Consumer unit replacement price guide
These all-in ranges show what replacing a consumer unit typically costs in London and the South East, overall £700–£1,200. They are published market guide figures, not our prices — we inspect and quote each installation individually, free of charge.
| Job | Guide figure* |
|---|---|
| Like-for-like main-switch board | £650–£850 |
| Dual-RCD split-load board, up to 10 circuits | £700–£950 |
| High-integrity board with RCBOs and surge protection | £850–£1,100 |
| Larger 12–16 way board or relocation | £950–£1,200 |
*Typical London and South East guide figure, not a fixed quote. Source: Fantastic Services UK price guides, updated 24 September 2026 (prices include VAT, London & South East column). Remedial work on the existing installation is extra. These figures are not our prices; your quotation is based on your property.
What affects the price
- Type of board and protection — split-load RCDs, individual RCBOs, surge protection
- Number of circuits and whether extra ways are needed for future work such as an EV charger or shower
- Moving the board to a new position
- Faults found when circuits are tested, which must be fixed before the new board can be energised
- Earthing and main bonding upgrades
- Testing, certification and Part P notification
We replace consumer units and old fuse boxes across Greenwich and Blackheath, Lewisham and Southwark, Bexley and Dartford and Gravesham and the surrounding area.
Want a price for your property? Ask for a free consumer unit & fuse board upgrades quotation.
07977 519533Enquire onlineWhen to call a registered electrician
- You still have rewirable fuses or no RCD protection.
- The board shows heat damage, smells or makes noise.
- You are planning an extension, new kitchen, shower or EV charger.
- An EICR has recommended a consumer unit upgrade.
David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.
Related services
- Consumer Unit & Fuse Board Upgrades — Replacement consumer units and fuse boards, with electrical testing and certification.
- Testing & Inspecting (EICR) — Electrical Installation Condition Reports for homeowners, buyers, landlords and businesses.
- Full or Partial Rewires — Complete and partial rewires for houses, flats and commercial premises — planned carefully around occupied homes.
Frequently asked questions
Can I replace a blown rewirable fuse myself?
Homeowners have traditionally done this, but using the wrong rating of wire removes protection. If a fuse keeps blowing there is a fault, and it should be investigated rather than refitted.
Will a new consumer unit stop my lights going off when a socket trips?
It can. With individual RCBOs or a sensible split of circuits, a fault on one circuit is less likely to switch off others.
Is a plastic consumer unit fitted before 2016 unsafe?
Not necessarily. It may be recorded on an inspection, but existing plastic units are not automatically dangerous; condition and location matter.
Why might the final price be higher than the board itself?
Because a new board can only be switched on safely once every circuit has passed testing. Existing faults, missing earthing or bonding, or a request to move the board add work beyond the unit itself.
Is a board with individual RCBOs worth the extra cost?
It often is if you want a fault on one circuit to switch off only that circuit, rather than several. Your electrician can explain whether it suits your installation and budget.
Official sources
Need this sorted? Get a free, fixed quote from a registered local electrician.
07977 519533Enquire onlineThis guide is general information about UK electrical regulations and good practice, and any prices are indicative only. For advice on your property, speak to a registered electrician.