Skip to content
Electricians Blackheath – David J Farrar & Associates

Guide · 8 min read

Consumer unit replacement: cost and what is involved

Plan a consumer unit replacement with indicative London costs, RCBO, SPD and AFDD advice, testing requirements and Part P notification explained.

Short answer

A straightforward domestic consumer unit replacement might require a budget of around £700–£1,500, with larger or more complex installations costing £1,500–£2,500 or more. These are indicative planning ranges only, not a tariff or a quote, and additional repairs can change the total. The job includes assessment, safe isolation, circuit testing, certification and Building Regulations notification, not simply exchanging a box.

What the replacement price should include

The consumer unit distributes the supply to your home’s circuits and contains their protective devices. Replacing it involves checking that the existing installation can safely connect to the new equipment. A useful quotation includes the enclosure, agreed circuit protection, installation labour, inspection and testing associated with the change, a labelled circuit schedule and the necessary certificates. Ask whether VAT is included in the final payable figure.

For initial budgeting, around £700–£1,500 can be a reasonable broad allowance for a relatively straightforward domestic replacement. A larger board, more circuits, AFDD provision, difficult access or extensive remedial work can move the budget towards £1,500–£2,500 or beyond. These are illustrative ranges, not independently surveyed London averages or guaranteed prices. David gives free fixed quotes after assessing the property and agreeing the specification.

Why one home costs more than another

Circuit count matters because every circuit needs suitable protection, identification, connection and testing. An installation with several lighting and socket circuits, electric heating, an outbuilding supply and dedicated appliances is not comparable with a small flat. The enclosure must have adequate space for the actual devices and sensible future capacity; a spare slot alone does not prove the whole supply can support future loads.

The existing equipment and location also affect labour. Short cables may need suitable extension arrangements; damaged meter tails or missing main bonding may need attention; cramped cupboards can make safe access difficult. Relocating the unit is a different scope from replacing it in place. A network operator or electricity supplier may need to deal with equipment that the electrician is not authorised to alter.

Ask for exclusions in writing: fault-finding beyond an agreed allowance, cable replacement, plastering, decoration, asbestos-related work, cupboard alterations and utility charges are common examples to clarify. An apparently low headline figure may omit work another quotation includes. Compare the finished safe installation and paperwork, not only the advertised board price or the number of hours expected on site.

RCBOs, RCDs and circuit breakers explained

A circuit breaker provides protection against overload and short circuit. An RCD detects residual current imbalance and disconnects in specified conditions, helping reduce electric-shock risk. An RCBO combines residual-current and overcurrent protection for an individual circuit. It is not correct to treat these names as interchangeable, and none removes the need for sound wiring, earthing, bonding and correct installation.

Individual RCBOs are often a useful choice because a fault on one circuit need not interrupt unrelated circuits through a shared RCD. This can improve convenience and help with fault identification, although upstream devices or supply faults can still cause a wider outage. The electrician must choose suitable device types and ratings for the connected loads, including electronic equipment, rather than assuming a single standard device suits everything.

New domestic consumer units normally use a non-combustible enclosure, commonly metal, as explained in IET guidance on consumer units. An existing plastic enclosure is not automatically dangerous solely because of its material. Its condition, location and protective arrangements matter. Ask why replacement is being recommended and whether a specific defect, lack of suitable protection or planned new circuits makes it appropriate.

Surge protection and arc fault detection

A surge protective device, or SPD, helps limit transient overvoltages that can damage connected equipment. The IET’s surge-protection guidance explains that protection is required where consequences include serious injury, failure of a safety service or significant financial or data loss. In other cases protection is normally provided unless the owner declares the risk and potential consequential loss tolerable. Omission is not a casual cost-saving decision where mandatory conditions apply.

An arc fault detection device, or AFDD, monitors characteristic signs of certain arcing faults associated with fire risk. It is different from an SPD and from an RCD. Under the A2 requirements, AFDDs are required for certain single-phase final circuits supplying socket-outlets rated up to 32 A in higher-risk residential buildings, HMOs, purpose-built student accommodation and care homes. They are recommended for those circuits in other premises; an ordinary rental flat is not automatically an HMO.

The designer should confirm the applicable edition and amendments of BS 7671 for the work, the building classification and the circuits affected. Ask for AFDDs to be identified separately in the specification so you understand the cost and rationale. Do not accept a blanket claim that every home must have them on every circuit, or that they are never relevant to a domestic upgrade.

Assessment before the change and faults uncovered

Electrical Safety First’s Wiring Regulations guidance supports checking the suitability of existing arrangements when alterations are undertaken. The electrician needs enough information about the installation before committing to a safe replacement. Depending on available records and condition, preliminary testing or a separate EICR may be sensible. A full EICR is not automatically the same service as the inspection and testing required for replacing a board.

Modern protective devices can reveal problems that old arrangements did not disconnect for, including insulation defects, shared neutrals or incorrect connections. This does not mean the new board created the underlying fault. Agree how discoveries will be reported, priced and authorised. A circuit that cannot be safely reconnected may need to remain isolated pending repair; nobody should bypass protection simply to make everything appear operational.

What happens on installation day

Expect a planned period without electricity while isolation, replacement, connections and testing take place. A straightforward replacement is often arranged over a working day, but faults, access or utility coordination can require extra time. The electrician should explain the likely outage before booking. Protect chilled food, arrange alternative working arrangements and tell them about medical equipment or services needing continuous power.

Clear the working area and keep children and pets away. Safe isolation may depend on arrangements at the meter or service position; do not remove seals or pull the supplier’s fuse yourself. After installation the electrician tests, labels the circuits and explains the main switch, test buttons and any indicator windows. A neat enclosure is not evidence that all the necessary testing has been completed.

Certification and Part P notification in England

GOV.UK’s Approved Document P identifies replacement of a consumer unit as notifiable work in an English dwelling. A suitably registered Competent Person Scheme installer can self-certify their own work and arrange notification through the scheme. Alternatively, an appropriate building control route must be arranged. Establish the route before work begins rather than expecting another electrician to approve hidden work afterwards.

You should receive an Electrical Installation Certificate with the relevant schedules and test results, plus the separate Building Regulations compliance documentation through the applicable route. An EICR is a condition report, not a replacement for the installation certificate. Check your address, the work description, circuit schedule and any recorded limitations. Keep digital copies for future maintenance, letting or a house sale. Wales has different notification provisions; Scotland uses a different building standards system.

Planning an upgrade in south-east London

Consumer units in Blackheath and Greenwich period homes are sometimes in under-stairs cupboards, cellars or awkward positions created during conversions. A survey should consider access, escape routes, damp conditions and available space without assuming the old position remains suitable. In converted flats, ownership of rising mains and shared cupboards may require the freeholder or managing agent to become involved.

If the building is listed, moving a board or cutting routes through historic joinery can require heritage advice or consent depending on the effect on character. This is separate from Part P. Plan the board specification alongside foreseeable kitchen, heating or garden projects, but do not assume a replacement alone increases the incoming supply capacity. Coordinated planning can prevent repeated disruption without adding equipment you do not need.

When to call a registered electrician

  • The consumer unit shows heat damage, burning smells or exposed parts.
  • An EICR identifies dangerous or potentially dangerous protective arrangements.
  • You need new circuits and the existing equipment cannot accommodate them safely.
  • Repeated trips persist and require proper diagnosis rather than repeated resetting.
  • You are planning a major refurbishment or changes to electric heating.

David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.

Related services

Frequently asked questions

Will a new fuse board make all my old wiring safe?

No. New protection cannot repair damaged insulation, missing protective conductors or unsafe concealed connections. Existing circuits must be assessed and tested, and any necessary repairs agreed. Sometimes a partial or full rewire is more appropriate than a board-only upgrade.

Do I need to replace a plastic consumer unit immediately?

Not solely because it is plastic. Condition, location, signs of overheating and protective arrangements affect the assessment. A registered electrician should explain the safety reasons for replacement rather than treating every older enclosure as an automatic failure.

Can I buy the consumer unit myself?

Discuss this before purchasing. The installer must be satisfied that the enclosure and protective devices form a suitable verified assembly and suit your installation. Supplying the wrong equipment can delay work and complicate responsibility for compatibility, warranties and replacement parts.

Is notification included in the price?

It should be clearly addressed in the written quotation because an English domestic consumer unit replacement is notifiable. Ask who will notify, by which route and what documents you will receive. Do not assume an electrical test certificate alone completes the Building Regulations process.

Will an RCBO stop every power cut?

No. Separate RCBOs can limit the impact of many circuit faults, but they cannot prevent network outages, main-switch isolation or every upstream trip. Correct design and testing matter more than promises that a particular board will never trip.

Official sources

Need this sorted? Get a free, fixed quote from a registered local electrician.

07977 519533Enquire online

This guide is general information about UK electrical regulations and good practice, and any prices are indicative only. For advice on your property, speak to a registered electrician.

Talk to an electrician today

Free quotations · No hidden fees · Domestic & commercial

Call nowFree quote