Short answer
Bathrooms need equipment selected for their zones, suitable protection against water and appropriate RCD protection. Kitchens do not have the same bathroom zoning rules, but socket positions must suit water, heat and appliance use. In England, new circuits, consumer-unit replacements and certain alterations in bathroom special locations are notifiable; not every kitchen alteration is.
The rules: safety standards and building control
Part P of the Building Regulations covers electrical safety in dwellings in England. GOV.UK’s Approved Document P explains ways to comply and which work needs notification. BS 7671, the Wiring Regulations, provides the principal technical framework for design, erection and verification. Building-control notification and electrical testing are related but different requirements.
All domestic electrical work must be safe, including work that is not notifiable. A minor alteration is not exempt from proper design, safe isolation and testing simply because building control does not need to be notified. A kitchen fitter’s overall refurbishment contract should clearly identify who is responsible for the electrical work and its certificates.
This guide is England-focused. Wales has different notification provisions, and Scotland uses its own building standards system. Do not apply the England notification thresholds to a property elsewhere. Ask the designer to confirm the applicable edition and amendments of BS 7671 at the design date rather than relying on an old diagram found online.
Bathroom zones: measure the actual room
Zone 0 is the interior of a bath or shower basin. Special rules also define zone 0 for showers without a basin. It is the most demanding water-exposure area, and equipment must be specifically suitable. Ordinary mains-voltage fittings do not become acceptable there just because their packaging describes them as waterproof.
For a bath or shower with a tray, zone 1 generally covers the space above the bath or tray to the relevant upper boundary, commonly 2.25 metres above finished floor level, with additional considerations where fixed water outlets are higher. Zone 2 generally extends 0.6 metres horizontally beyond zone 1, subject to the applicable design rules.
A shower without a tray has different geometry, including a zone 1 extent generally measured 1.2 metres from the fixed water outlet, rather than simply adding the tray-based zone 2 diagram. Partitions, sloping ceilings, fixed outlets and the usable space can affect assessment. Have the electrician mark the zones on the actual layout.
These descriptions explain the principles, not every exception or permitted equipment type. Do not use them to choose fittings independently for an unusual wet room. A basin does not automatically create the same formal zones as a bath or shower, but foreseeable splashing still matters when selecting and locating equipment.
IP ratings describe water protection, not complete suitability
Typical minimum water-protection levels are IPX7 in zone 0 and IPX4 in zones 1 and 2. Where water jets are likely, equipment may need at least IPX5. The X means the dust or solids digit is not specified in that shorthand; it is not a product grade in itself.
An IP rating does not prove that a fitting is permitted in every zone. Supply voltage, equipment type, manufacturer’s instructions and the precise installation arrangement also matter. Zone 0 equipment has strict extra-low-voltage and suitability requirements, including restrictions on where its power source can be located. Leave that selection to the electrical designer.
Recessed fittings may need other characteristics, such as suitability for insulation coverage or the required ceiling fire performance. These are separate from water protection. Keep product instructions and do not substitute a visually similar downlight without checking all relevant ratings, especially in flats where the ceiling may form part of fire separation.
RCD protection, sockets and bathroom appliances
Bathroom circuits normally require additional protection by a 30 mA RCD under modern domestic design requirements. Electrical Safety First’s bathroom guidance explains the importance of RCD protection and using a registered electrician. An RCD is additional protection: it does not allow unsuitable equipment, remove the need for earthing or make extension leads safe beside water.
Ordinary sockets have strict separation requirements from baths and showers, while appropriate shaver-supply units follow their own rules. Because the detailed socket-distance provisions depend on the applicable BS 7671 edition and amendments, have the designer confirm the current requirement on the drawing. Do not assume that being outside zone 2 alone permits an ordinary socket.
Never run an extension lead into a bathroom to power a hairdryer or portable heater. Select fixed heaters, fans and towel rails for the location and follow manufacturer restrictions. Electric showers normally need their own correctly designed circuit, suitable isolation and assessment of supply capacity; replacing a shower with a more powerful model is not a like-for-like decision.
Bonding arrangements also need professional assessment. The presence of an RCD does not automatically mean every existing bonding conductor can be removed. Your electrician must verify the installation conditions and protective measures before deciding what is required. Do not disconnect earth or bonding connections during plumbing alterations.
Kitchen sockets near sinks and hobs
Kitchens do not use the bathroom zone system merely because they contain a sink. Socket positions still need to avoid foreseeable water, heat, mechanical damage and trailing leads. A commonly used design recommendation is at least 300 mm horizontally from the edge of a sink or draining board, but this is guidance, not a universal statutory clearance.
Meeting that distance alone does not make a location suitable. Consider tap reach, splashing, the appliance position and the instructions for both accessories and equipment. Avoid sockets directly behind hobs or where flexes would cross hot surfaces. Agree locations on a measured plan before units, splashbacks and tiling are finalised.
Provide enough suitably located outlets for normal use rather than planning around multiway adaptors. Larger fixed appliances may require dedicated circuits or specific connection arrangements depending on their load and instructions. The electrician should calculate demand and check the existing installation, not assume that an available socket means the circuit can support another high-power appliance.
Isolation for integrated appliances should be practical and clearly identified. A repair should not depend on dragging a heavy appliance out while it may still be faulty. Discuss accessible switching, connection points and service access with the kitchen designer and electrician together; exact arrangements depend on the appliance and layout.
Which jobs are notifiable in England?
Under the England framework explained in Approved Document P, installing a new circuit or replacing a consumer unit is notifiable domestic electrical work. Additions and alterations to existing circuits within a defined special location around a bath or shower can also be notifiable. That notification area needs checking against the legal definition, not casual room labels.
A kitchen is not, by itself, a special location for England notification purposes. Adding a socket to a suitable existing kitchen circuit is therefore not automatically notifiable solely because it is in the kitchen. A new cooker circuit remains notifiable because it is a new circuit, regardless of where it is installed.
Like-for-like replacement and repairs can have different notification treatment from additions, but still need safe completion and appropriate testing. For notifiable work, agree the route before starting: a registered competent-person installer can normally self-certify work within their scheme scope, or a suitable building-control route must be arranged. Do not assume retrospective paperwork will be straightforward.
Period homes and converted flats in south-east London
In Blackheath, Greenwich and Lee, bathroom and kitchen refurbishments often take place in older homes with later extensions or conversions. Existing circuits may not match room boundaries, and concealed junctions may become apparent only when old units are removed. Arrange early assessment before finalising the refurbishment budget and decorating sequence.
In converted flats, check permissions for new extraction routes, shared access and any work affecting fire-resisting ceilings or walls. The electrician, plumber and builder should coordinate holes, cable routes and sealing. A well-rated fitting cannot compensate for inappropriate openings or damage elsewhere in the construction.
Rented flats need clear coordination between owner, agent and trades. A current condition report is useful background but does not automatically cover new installation work. Keep the refurbishment certificates alongside the existing electrical records, and address any immediate defects rather than waiting for the next periodic landlord inspection.
Plan the installation and keep the right paperwork
Before work begins, agree appliance loads, fitting specifications, zones, circuit arrangements and accessible isolation. Confirm the design standard, notification responsibility and what is excluded, such as plastering, tiling or decorating. David gives free fixed quotes for defined work, allowing the electrical scope to be coordinated with the wider refurbishment.
On completion, obtain the appropriate Electrical Installation Certificate or Minor Electrical Installation Works Certificate for the work undertaken. Where notification applies, also obtain the Building Regulations compliance documentation. An EICR assesses condition and is not a substitute for certifying newly installed work.
Keep instructions for fans, showers, heating controls and protective devices, including RCD test guidance. Ask how to isolate each fixed appliance and what to do if a protective device operates. Planning these details makes the completed room easier to maintain without encouraging unsafe access behind fitted cabinets or bathroom equipment.
When to call a registered electrician
- You are changing the bathroom layout or creating a wet room.
- A new shower, cooker or other high-load appliance is planned.
- RCD protection, earthing or bonding arrangements are uncertain.
- New circuits or a consumer-unit replacement may be required.
- Sockets or fittings show moisture damage, heat or deterioration.
David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.
Related services
- Additional Sockets — More sockets where you need them — fewer extension leads, less overloading.
- Electrical Showers & Hot Tubs — Dedicated, correctly-rated circuits for electric showers and hot tubs, certified to Part P.
- Consumer Unit & Fuse Board Upgrades — Replacement consumer units and fuse boards, with electrical testing and certification.
Frequently asked questions
Is 300 mm from a kitchen sink a legal rule?
It is commonly used positioning guidance, not a universal statutory separation. The actual design must address splashing, heat, appliance instructions and use. A socket can still be poorly positioned even if it meets that distance.
Does every bathroom light need IP65?
No. The required protection depends on the zone and exposure, and other suitability requirements also apply. IP65 may be appropriate for a particular fitting, but it is not a substitute for assessing location, equipment type and installation conditions.
Is all kitchen electrical work notifiable?
No, not in England. A new circuit or consumer-unit replacement is notifiable, but a suitable alteration to an existing kitchen circuit is not automatically notifiable just because of the room. Wales has different provisions.
Can I replace a shower with a more powerful one?
Only after the circuit, protective equipment, isolation and supply capacity have been checked. Existing cable size alone is not enough to establish suitability, because installation method and other design factors affect capacity.