Skip to content
Electricians Blackheath – David J Farrar & Associates

Guide · 8 min read

EICR explained: how often do you need one?

Understand EICR checks, homeowner inspection intervals and landlord duties in England, with practical advice for south-east London properties.

Short answer

An Electrical Installation Condition Report records whether existing fixed electrics are satisfactory for continued use. Electrical Safety First recommends inspection every ten years for owner-occupied homes; private landlords in England must arrange it at least every five years, or sooner if the report requires. Warning signs, damage or a change in use can justify an earlier inspection.

What an EICR does and does not cover

An EICR is the written result of inspecting and testing an existing electrical installation. It covers items such as the consumer unit, circuit wiring, earthing, bonding, sockets and fixed lighting within the agreed scope. The inspector combines visible checks with instrument tests to identify deterioration, damage, unsuitable alterations and conditions that could cause danger. A working socket alone cannot demonstrate that its protective arrangements are effective.

It is not a promise that nothing will ever go wrong, and it does not automatically include every appliance plugged into a socket. Appliance checks, specialist equipment and communal installations may need separate arrangements. Agree the scope before booking, particularly in a flat where your own installation ends at a different point from the landlord’s shared supply. An electrical health check without recorded testing is not an equivalent substitute.

How often homeowners should arrange inspection

Electrical Safety First recommends periodic inspection and testing every ten years for an owner-occupied home. This is a general recommendation, not a universal statutory ten-year expiry date for every homeowner. An inspector can recommend a shorter interval based on condition, age, use and maintenance. Read the next-inspection recommendation on your existing report rather than assuming that every satisfactory result buys another decade.

Arrange earlier advice after flooding, fire damage, major alterations or repeated unexplained tripping. Buying an older home with missing records is another sensible trigger: an ordinary building survey may not include electrical testing. Before a substantial kitchen refurbishment, inspection can identify circuit limitations while changes are still easy to plan. Do not wait for the normal interval if accessories become hot, crackle or smell burnt.

The five-year rules for private landlords in England

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require relevant installations to be inspected and tested by a qualified person at intervals of no more than five years. If the report specifies an earlier date, that shorter interval applies. Landlords must ensure the relevant safety standards are met during the tenancy, not simply order a report and file it regardless of the findings.

GOV.UK’s rented-sector guidance explains the duties and exemptions and now also addresses the extension to social rented housing. This guide focuses on private lettings in England. A valid existing report can normally continue across a change of tenant if it remains suitable and within its recommended interval; a new tenancy does not automatically require another full EICR. Check for damage and changes between occupancies, and obtain advice where the property’s condition has altered.

Give an existing tenant the report within 28 days of the inspection, a new tenant a copy before occupation, and a prospective tenant a copy within 28 days of their request. Supply it to the local authority within seven days of a written request. Keep a copy for the next inspector. These are separate obligations from arranging any repairs, so maintain a dated record of both reporting and remedial action.

Understanding satisfactory, C1, C2, C3 and FI

The overall outcome is satisfactory or unsatisfactory, supported by observations and classification codes. C1 means danger is present and immediate remedial action is required. C2 means potentially dangerous and requires urgent remedial action. FI means further investigation is required without delay. C3 means improvement is recommended; a C3 observation alone does not make an EICR unsatisfactory. Ask the inspector to explain the actual defect, not merely quote a code.

For relevant rented properties, required remedial work or further investigation must normally be completed within 28 days, or sooner where the report specifies a shorter period. Immediate danger must not be left for 28 days. Obtain written confirmation of completion and provide the required report and confirmation to the tenant and council within the applicable 28-day period after completion. Do not assume a verbal assurance or an invoice without supporting details closes the matter.

Older installations need not be condemned merely because they do not match every feature of today’s new installations. Assessment considers safety, condition and the circumstances. Equally, age is not a defence for damaged insulation or ineffective protection. Ask for a clear connection between each observation, its safety significance and the proposed remedy; a report should not be used simply to sell a rewire.

What happens during the appointment

The electrician will identify circuits, inspect accessible equipment and carry out appropriate tests. Some testing requires the power to be off, and sensitive equipment may need disconnecting. Provide previous certificates, circuit schedules and details of extensions, outdoor supplies or recurring faults. Tell the electrician about medical equipment, security arrangements, home working and anything else that cannot lose power without careful planning.

Clear access to the consumer unit, sockets, loft hatches and any agreed inspection points. Inspection involves sampling and agreed limitations rather than dismantling every wall or lifting every floor. Any restrictions should be recorded, including their effect on the report’s usefulness. A cheap inspection with extensive unexplained limitations may be poor value. Ask how long the appointment is expected to take for your property rather than comparing prices alone.

Blackheath, Greenwich and converted London homes

Victorian and Georgian houses around Blackheath and Greenwich may contain several generations of alterations. A modern-looking consumer unit does not prove that cables elsewhere were renewed. Conversions in Lewisham and Lee can have shared cupboards, supplies crossing another flat or unclear circuit labels. These are reasons to plan access and establish ownership, not assumptions that every period home is unsafe.

For a rented flat, clarify whether the booking includes only the dwelling or any landlord-controlled communal circuits. Speak to the freeholder or managing agent where shared areas are involved. Historic finishes and fitted flooring can limit access, so explain them at quotation stage. Where work may affect a listed building’s character, plan consent and routing before remedial installation work begins; an EICR itself is not heritage permission.

Choosing the inspector and comparing quotations

Choose someone competent in periodic inspection and testing of the type of installation involved. The Registered Competent Person Electrical website can help identify businesses offering domestic safety reports; check the relevant scheme and scope. Registration is useful evidence, but ask specifically about inspection experience, insurance and how reports are reviewed. Installation competence and inspection competence overlap without being identical tasks.

Request a written quotation identifying the property, number of consumer units, inspection scope, access assumptions, report delivery and whether VAT applies. Keep remedial work separate unless you knowingly authorise it. David J Farrar & Associates provides free fixed quotes after establishing the requirements. A quotation should make clear whether further visits, specialist access or investigation outside the initial scope would incur an agreed additional charge.

Keeping the report useful between inspections

Save the complete report, not just the summary page, alongside schedules of test results, installation certificates and subsequent remedial records. Put the next recommended date in your calendar, allowing time for access and repairs. Landlords should also record when copies were supplied to tenants. Good records help the next electrician understand what changed and reduce uncertainty when a property is sold or re-let.

Between formal inspections, report damaged accessories, heat marks and repeated trips promptly. Follow the manufacturer’s instructions for user testing of RCDs; pressing a test button does not replace an EICR. Do not remove the consumer-unit cover or investigate live wiring yourself. Wales and Scotland have their own housing requirements, so do not apply England’s landlord deadlines to properties elsewhere without checking the relevant national guidance.

When to call a registered electrician

  • Your report’s recommended inspection date is approaching or has passed.
  • You are preparing a property for letting without suitable electrical records.
  • Sockets show heat damage, crackling or a burning smell.
  • Circuits repeatedly trip or a previous defect remains unexplained.
  • Flooding, a fire or significant alterations may have affected wiring.

David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.

Related services

Frequently asked questions

Is an EICR compulsory when I sell my home?

There is no general requirement for an ordinary owner-occupier in England to obtain an EICR solely to sell. Buyers, lenders or solicitors may request electrical information, and inspection can help resolve uncertainty. It does not retrospectively provide missing Building Regulations approval.

Does a satisfactory EICR last exactly five years?

Not necessarily. Five years is the maximum normal interval under the relevant private rented rules, while an inspector may require an earlier inspection. Significant changes or damage can also justify checking sooner. Read the recommendation and any limitations on the actual report.

Does C3 mean my rental property has failed?

A C3 observation by itself does not make the overall result unsatisfactory. It recommends an improvement. Ask what benefit the improvement offers and plan it appropriately, while prioritising C1, C2 and FI observations and any other duties that apply.

Can the inspector repair faults during the visit?

Sometimes a small repair can be completed with your agreement, but inspection and remedial work are different services. Agree authority, prices and documentation first. Serious danger may require immediate isolation, while more extensive repairs usually need a separate scope and appointment.

Will the electricity be off all day?

Testing needs planned interruptions, but their duration depends on the installation and access. Ask beforehand rather than assuming uninterrupted power. Tell the electrician about medical equipment, alarms and refrigerated stock so a safe arrangement can be agreed before work starts.

Official sources

Need this sorted? Get a free, fixed quote from a registered local electrician.

07977 519533Enquire online

This guide is general information about UK electrical regulations and good practice, and any prices are indicative only. For advice on your property, speak to a registered electrician.

Talk to an electrician today

Free quotations · No hidden fees · Domestic & commercial

Call nowFree quote