What are earthing and bonding, and when are they checked?

Learn what earthing and bonding do, how main and supplementary bonding differ, and when an electrician may check them.

Short answer

Earthing provides a path for fault current so protective devices can disconnect a supply, while bonding connects relevant metal parts to reduce dangerous voltage differences. Main bonding and supplementary bonding have distinct purposes; an electrician checks whether the arrangement is appropriate for the installation rather than adding connections indiscriminately.

Earthing and bonding do different jobs

Earthing connects exposed conductive parts of electrical equipment to the installation's earthing arrangement. If a fault makes a metal case live, the path can help the protective device disconnect the supply. The effectiveness depends on the complete system, including the supply arrangement and protective devices, so a visible wire alone does not prove that earthing is adequate.

Bonding connects selected conductive parts together and, where required, to the main earthing terminal. Its purpose is to limit a hazardous potential difference between parts that could be touched at the same time. Bonding is not a substitute for earthing, and neither function should be judged by appearance or by the presence of a green-and-yellow conductor alone.

Main protective bonding

Main protective bonding is associated with incoming services and the building's main earthing terminal. Depending on the installation and applicable requirements, relevant extraneous-conductive-parts may include metallic water or gas service pipework. The assessment considers whether a part can introduce a potential from outside, its material and continuity, and the installation's earthing arrangement.

A plastic section of pipe, a meter, or a visible clamp does not by itself settle whether bonding is required or correctly located. Services can be altered during plumbing work, and connections can become inaccessible, loose or unsuitable. A qualified electrician can identify the relevant parts and verify the arrangement using inspection and appropriate tests.

Supplementary bonding

Supplementary bonding links simultaneously accessible conductive parts locally, where a particular location or installation requires it. It has historically been associated with some bathrooms and other special locations, but it is not automatically required in every modern bathroom. The applicable rules, protective measures and characteristics of the circuit determine whether it is needed.

Do not add a bonding wire because a room contains metal taps or a bath, and do not remove one because it looks redundant. The electrician must consider the actual circuit protection, earthing continuity and relevant requirements in BS 7671. Local supplementary bonding cannot correct a defective main earthing arrangement or a fault elsewhere in the installation.

When an electrician may check it

Earthing and bonding are relevant during an Electrical Installation Condition Report (EICR), alterations, consumer unit work, or investigation of a shock, tingling sensation or electrical fault. An electrician may also check them after significant changes to incoming services or when a property has an older installation with unclear history. Testing scope depends on the work requested and the installation's condition.

An EICR involves inspection and testing against the relevant requirements and limitations agreed for the report. It is not simply a visual check of one clamp. The electrician may need access to the consumer unit, service entry points and other areas. Tell them about previous alterations, inaccessible areas, unusual shocks or known plumbing changes so findings can be interpreted properly.

What inspection and testing establish

The electrician identifies the earthing arrangement, checks accessible connections and assesses whether the required paths are present and effective. Depending on the job, tests may include continuity and other electrical measurements. Instruments and test methods must be suitable, and results are considered alongside visual inspection and the installation's design; a quick glance cannot establish safety.

If a concern is found, the electrician should explain the observation, its significance and any recommended corrective work. The response may involve repair, further investigation or a documented limitation where access is not available. Do not rely on a seller's assurance or an old label instead of obtaining an inspection appropriate to the property's present condition.

Mistakes to avoid

Do not confuse bonding with an earth wire for an appliance, or assume every metal pipe needs a clamp. A redundant-looking connection may serve a purpose, while a visible clamp may not be electrically effective. Removing, relocating or adding bonding without an assessment can create risk and may conceal a different defect.

Never use a gas or water pipe as an improvised earth, and do not test a connection with a homemade method. Avoid touching conductors or dismantling service clamps. Report tingling taps, pipework or appliance cases promptly and stop using suspect equipment if safe; an electrician can assess the installation without relying on guesswork.

Ask for the inspection findings to distinguish urgent danger from recommended improvement. In a report, the outcome depends on the condition found and the report's scope. A satisfactory result does not mean every possible part of an installation has been opened or assessed; limitations should be recorded and explained.

If work is carried out, keep the relevant electrical documentation. In England, some domestic electrical work is subject to Part P building regulations, but applicability depends on the work. Ask the electrician what certification or notification is appropriate rather than assuming every bonding check has the same paperwork.

When to call a registered electrician

  • Call an electrician promptly if anyone feels a shock or tingling from metalwork or an appliance.
  • Request checks after alterations to gas or water services, a consumer unit change or suspected damage.
  • Arrange an EICR if the condition or earthing arrangement is unknown and a suitable inspection is due.
  • Ask for advice if a clamp or bonding conductor appears loose, damaged or has been removed; do not adjust it yourself.

David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.

Related services

Frequently asked questions

Is earthing the same as bonding?

No. Earthing provides a fault-current path for exposed conductive parts, while bonding connects selected conductive parts to limit dangerous voltage differences. They work within the overall protective arrangement but have separate functions.

Does every bathroom need supplementary bonding?

Not necessarily. Whether local supplementary bonding is required depends on the installation and the protective measures in place under the applicable requirements. An electrician should assess the actual circuits rather than use a blanket rule.

Should all metal water and gas pipes be bonded?

The electrician assesses relevant incoming services and conductive parts against the installation requirements. Material, continuity and the earthing arrangement matter; do not add or remove a clamp based solely on a pipe's appearance.

Can I check bonding by looking for a green-and-yellow wire?

Visual identification can be a useful clue but cannot establish continuity, adequacy or correct connection. Inspection and, where appropriate, testing by a qualified electrician are needed to assess it reliably.