An EICR is only part of a landlord’s electrical safety responsibilities in England. Keep the installation safe, act on urgent findings, meet report-sharing deadlines and maintain the required smoke and carbon monoxide alarms. Check supplied appliances, licensing conditions and records too; the former £30,000 electrical-safety penalty ceiling increased to £40,000 in November 2025.

Confirm your duties and put dates in one place

This checklist focuses on private landlords in England. The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 established inspection and related duties; subsequent amendments extended the framework to social housing. GOV.UK’s current guidance explains the requirements and transition arrangements. Wales and Scotland use different rented-sector legislation, so do not transfer these deadlines unchanged to a property elsewhere.

Identify the correct property, landlord and tenancy, then collect the latest electrical report, installation certificates and outstanding repair information. Check whether any tenancy or property exemption actually applies rather than assuming a short let or family arrangement is exempt. Seek competent advice where the arrangement is unusual.

Use a compliance diary with reminders well before inspection dates, licence renewals and alarm replacement dates. Record who arranges access, who approves repairs and who sends reports to tenants. An agent can help carry out the work, but delegating administration is not a reason for the landlord to ignore missed deadlines or known hazards.

Arrange the EICR and read the complete report

Arrange inspection and testing of the fixed installation by a qualified and competent person at intervals of no more than five years, or sooner if the report requires. GOV.UK’s landlord guidance explains that the installation must meet the applicable safety standards. A report is evidence of assessment, not permission to ignore faults that develop between inspections.

Check that the report identifies the right flat or house and includes the schedules, observations, overall outcome and next inspection date. Review the extent and limitations. If a garage, garden circuit or part of the installation could not be inspected, establish whether further access or assessment is needed rather than assuming it passed.

Before the visit, provide previous reports and arrange access to the consumer unit, sockets and relevant spaces. Explain supplied equipment and known problems. A new tenancy does not automatically require a fresh full EICR if a valid report remains appropriate, but check condition between occupancies and investigate evidence of damage or unauthorised alteration.

Meet remedial and report-sharing deadlines

Provide the report to existing tenants within 28 days of the inspection and to new tenants before occupation. Give it to prospective tenants within 28 days of a written request, and to the local housing authority within seven days of a written request. Retain a copy for the next inspector. These are separate duties, not optional administrative extras.

Where the report requires remedial work or further investigation, arrange it within 28 days or the shorter period specified. C1 danger needs immediate action; do not treat the outer deadline as permission to leave an exposed live part energised. C2 means potentially dangerous, FI requires further investigation without delay, and C3 is an improvement recommendation.

Obtain written confirmation from a qualified person that the required work has been carried out and the standards are met, or that more work is needed. Supply that confirmation with the original report to tenants and the council within the required 28-day period after completion. Repeat the process if further necessary work is identified, retaining a traceable record of each stage.

Check smoke and carbon monoxide alarms separately

GOV.UK’s guidance on the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 requires at least one smoke alarm on each storey with a room used as living accommodation. A carbon monoxide alarm is required in a room used as living accommodation containing a fixed combustion appliance, excluding gas cookers. A bathroom or lavatory counts as living accommodation for these rules.

Check the required alarms work on the day a new tenancy begins. Record the check, locations and any action taken; a signed inventory entry can help evidence the process. When informed of a fault and it is found to be faulty, arrange repair or replacement as soon as reasonably practicable. Do not wait for the next electrical inspection.

These minimum rules do not specify every detail of a suitable fire alarm system. Building Regulations, fire-risk assessment and HMO licence conditions may require more extensive detection, interlinking or other measures. Follow manufacturer instructions for positioning and replacement. An EICR does not, by itself, confirm that the property has a complete and suitable fire detection strategy.

Inspect supplied appliances and use PAT sensibly

Keep appliances supplied with the tenancy safe, including fridges, washing machines, cookers and small appliances. Maintain an inventory recording the make, model, location and available serial number. Check recall information and register products where appropriate so safety notices can reach you. Remove unsafe items from use rather than leaving a warning label as the only response.

Inspect plugs, flexible leads, casings and signs of overheating or water damage between tenancies and during appropriate visits. Electrical Safety First explains that appliance inspection and testing involves visual checks and relevant electrical tests by a competent person. A sticker alone is not a useful substitute for an identifiable record and action on failures.

There is no blanket rule requiring annual PAT for every appliance in every private rented home in England. Choose a risk-based inspection and testing programme taking account of equipment, use, condition, manufacturer information and any licence requirements. Social rented housing has additional equipment duties under the updated regulations; do not assume private-sector practice answers every social-landlord obligation.

Check HMO licensing and shared-area responsibilities

GOV.UK explains that an HMO generally involves at least three people from more than one household sharing facilities. Mandatory licensing generally applies to a large HMO with five or more people from more than one household sharing facilities, subject to the relevant legal definitions and exclusions. Smaller HMOs can require licensing under local schemes, so check with the council.

Read the actual licence conditions and the property’s fire-risk requirements. Shared kitchens, common stairs, emergency lighting and detection systems may need inspections or maintenance beyond the individual flat’s EICR. Assign responsibility clearly where a freeholder, managing agent and individual landlord are all involved. A certificate for one dwelling does not automatically cover communal equipment.

For properties in Lewisham, Greenwich, Bexley or neighbouring boroughs, check the current council licensing arrangements for the specific address. Schemes and conditions can differ across borough boundaries. A Victorian house converted into rented flats may also raise management and fire-safety questions that cannot be answered simply by counting consumer units.

Carry out practical checks between formal inspections

Electrical Safety First recommends visual checks annually and between tenancies. Look for cracked accessories, scorch marks, damaged leads, missing covers and evidence of water ingress. Do not remove socket fronts or consumer unit covers during a landlord walk-round. Ask a competent electrician to investigate anything that needs access to live or concealed parts.

Make sure tenants know how to report faults promptly and how to identify the consumer unit safely. Give manufacturer-based advice on user testing of RCDs where applicable. Explain that repeated tripping, electric shocks, burning smells or hot accessories need attention, and that tenants should not attempt electrical repairs or defeat protective devices.

In period properties around Blackheath and Lee, check extensions, loft rooms and garden supplies as well as the main living rooms. Later additions may have different installation histories. Keep access and ventilation around electrical equipment clear, and ensure any work affecting shared walls or escape routes preserves the necessary fire separation.

Keep evidence and understand enforcement

Retain the complete EICR, proof of delivery, repair instructions, completion confirmation, invoices and installation certificates. Keep an alarm inventory, tenancy-start check record, appliance records and relevant licence conditions. Store dates and versions clearly so you can show what was known, what was done and when, rather than producing an unlabelled folder after a complaint.

If access is refused, document appointment offers, correspondence and reasonable steps taken. GOV.UK guidance explains the importance of evidence when access prevents compliance. Do not assume one unanswered message removes the duty, and do not enter unlawfully. Obtain advice and continue proportionate efforts to resolve access while addressing any immediate danger appropriately.

Older guidance referred to electrical-safety penalties up to £30,000. Regulation 11 now sets a £40,000 maximum following the November 2025 amendment; continuing failures can attract further penalties. Alarm enforcement and HMO offences have separate rules and consequences. David J Farrar & Associates can help with local inspections and remedial work, providing free fixed quotes for the agreed scope rather than treating paperwork as a substitute for safety.

When to call a registered electrician

  • The EICR is approaching its due date or specifies a shorter inspection interval.
  • A report contains C1, C2 or FI findings or leaves important areas unassessed.
  • A tenant reports shocks, overheating, burning smells or recurring trips.
  • Required alarms are missing, faulty or need upgrading under an agreed fire-safety specification.
  • A supplied appliance is damaged or the appropriate inspection and testing programme is unclear.
  • You are converting a property, changing occupancy or need the electrical scope separated from communal systems.

David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.

Related services

Frequently asked questions

Is an EICR enough to meet all my landlord duties?

No. You must act on findings, share reports, maintain safety between inspections and meet separate alarm and other applicable requirements. Appliances, licence conditions and common parts may need their own checks and records.

Do landlords need PAT every year?

There is no universal annual PAT requirement for all private rented homes in England. Supplied equipment must be safe. Set inspection and testing intervals by risk and check any HMO licence conditions or other applicable duties.

Can I wait 28 days to repair a C1 fault?

No. C1 means danger is present and immediate action is needed. The statutory outer timescale does not override a shorter period specified in the report or justify leaving an immediately dangerous situation untreated.

Are battery smoke alarms always sufficient?

The baseline England alarm rules do not mandate one power type for every property, but other requirements can demand a more extensive system. Check Building Regulations, the fire-risk assessment, licence conditions and manufacturer instructions.

Is the maximum electrical-safety fine still £30,000?

No. That was the earlier ceiling. The England electrical-safety regulations were amended in 2025 and regulation 11 now provides a maximum of £40,000. Other housing or alarm breaches can have separate enforcement consequences.

Official sources

Need this sorted? Get a free, fixed quote from a registered local electrician.

07977 519533Enquire online

This guide is general information about UK electrical regulations and good practice, and any prices are indicative only. For advice on your property, speak to a registered electrician.

Talk to an electrician today

Free quotations · No hidden fees · Domestic & commercial

Call nowFree quote