Skip to content
Electricians Blackheath – David J Farrar & Associates

Guide · 5 min read

Cat5e or Cat6: which network cable should you choose?

Compare Cat5e and Cat6 for network points, existing wiring, PoE and future upgrades, including testing and installation planning.

Short answer

Cat5e can support a gigabit network when the complete link meets the required standard. Cat6 offers more performance headroom and is a sensible option for new network points. Keep sound existing cabling unless testing or your actual requirements justify replacement; neither category alone guarantees faster broadband.

Start with the connection you actually need

A network cable connects equipment within your property; it does not determine the speed supplied by your internet provider. For ordinary browsing, video meetings and streaming, a reliable gigabit connection is often sufficient. Copying large files between local computers and network storage can place greater demands on the internal network, even when the broadband connection is relatively modest.

Write down the devices and destinations before choosing a cable category. A desk, television and ceiling access point have different locations and may need different numbers of outlets. Include printers, security equipment and likely room changes. This turns a vague request for faster internet into a practical specification that an installer can assess without promising results the broadband service cannot deliver.

What Cat5e and Cat6 mean

Cat5e and Cat6 describe performance categories for balanced twisted-pair cabling. Both can support 1000BASE-T, commonly called gigabit Ethernet, over a compliant channel up to 100 metres. That channel includes patch leads and connections, not just the cable hidden in the wall. Cat6 has tighter performance requirements, including better control of unwanted signal coupling between pairs.

The category is not a direct statement of internet speed, nor does it describe only the printed label on a reel. Cable, outlets, patch panels, patch leads and workmanship all contribute to the finished link. A Cat6 cable terminated onto unsuitable components does not automatically create a Cat6 installation. Ask what performance will be specified and how it will be demonstrated at handover.

Should existing Cat5e stay in place?

If existing points reliably meet your needs, wholesale replacement may create disruption without a useful improvement. Have suspect links assessed rather than assuming their age or category explains every dropout. Damaged leads, poor terminations, faulty ports and network settings can all cause symptoms that a new cable category would not necessarily solve.

Replacement becomes more attractive when walls are already open, routes are accessible or a business has a clear requirement beyond the existing installation's tested capability. Ask the installer to distinguish reusable links from genuinely inadequate ones. Retaining satisfactory cabling in some rooms while installing Cat6 for new points can be a proportionate approach, provided records clearly identify what is installed where.

What if you want faster networking later?

Cat6 can support some shorter 10-gigabit links, but it should not be treated as a blanket promise of 10 gigabits throughout a building. Distance, interference from neighbouring cables and the complete installation affect suitability. Fluke Networks explains that existing Cat6 links need assessment for this use; Cat6A is designed to support 10GBASE-T over a 100-metre channel.

For a genuine future requirement, describe the application and route lengths rather than simply asking for the highest number. Confirm any specification beyond the advertised Cat6 network-point service separately. Switches, computer interfaces and storage must also support the intended speed. An expensive cable upgrade cannot make a gigabit-only switch deliver a faster connection, and faster local networking will not remove a broadband bottleneck.

Plan routes, power and the physical environment

Cable choice also depends on where the link will run. Tight spaces, bend limits, cable supports, fire stopping and separation from mains wiring need professional planning. Cat6 products can be less flexible than some Cat5e products, so an existing route may require assessment. Shielding is not automatically better: its use should follow a coherent design rather than a marketing preference.

For outdoor points or a separate building, ordinary indoor cable may be unsuitable. Moisture, sunlight, mechanical damage and electrical differences between buildings require a site-specific solution; the designer may recommend a different link medium. Where new mains supplies are needed for network equipment, use a qualified electrician. Applicable fixed electrical work should follow BS 7671, with domestic Building Regulations requirements considered where relevant.

Specify testing and a useful handover

Ask for labelled outlets, a matching patch-panel schedule and test evidence appropriate to the agreed category and scope. A basic continuity check can identify wiring errors but does not establish every transmission-performance requirement. Agree whether formal link certification is included, how results will identify each outlet and what happens if a link fails the specified test.

Also agree where the network equipment will live, allowing access, ventilation and sensible cable management. Check whether the work includes only passive cabling or also switch configuration and reconnection of devices. Advertised data-network services include Cat6 points, patch panels and comms cabinets; additional specialist IT requirements should be confirmed rather than assumed. Keep drawings and results for future maintenance and room changes.

Mistakes to avoid

  • Replacing all working Cat5e without checking whether the actual problem is Wi-Fi coverage, a damaged patch lead or the broadband service.
  • Assuming a cable marked Cat6 guarantees a compliant end-to-end link regardless of outlets, patch leads and termination quality.
  • Ordering cable solely by category while overlooking routes, external exposure, fire stopping and safe separation from electrical circuits.
  • Planning only today's desk position and leaving no labelled spare points for an access point or future room layout.

When to call a registered electrician

  • Ask a data-cabling installer to assess persistent slow links, missing test records or a planned office refit before choosing replacement cable.
  • Use a qualified or registered electrician where network changes require additional sockets, new circuits or investigation of damaged electrical supplies.

David J Farrar & Associates are Part P, NAPIT and NICEIC registered with over 35 years' experience across Blackheath, Lewisham, Greenwich, Bexley and North Kent. Call 07977 519533 or send an enquiry for a free, fixed quotation.

Related services

Frequently asked questions

Will Cat6 improve my Wi-Fi?

It can provide a reliable wired connection to an access point, but radio coverage still depends on access-point position, building materials and configuration. Changing a cable alone does not guarantee stronger wireless coverage.

Can Cat5e and Cat6 be used together?

Yes, compatible Ethernet equipment can use both. Each complete link must be judged on its own components and test results; mixing categories does not upgrade the lower-performing parts.

Is Cat6 suitable for Power over Ethernet?

Appropriately specified Cat6 can carry standards-based PoE. The designer must also consider conductor quality, connectors, bundle heating, power requirements and equipment compatibility, rather than relying only on the category.

Should every room have two network points?

There is no universal requirement. Decide from the equipment, likely layout changes and disruption involved in adding points later. A written outlet schedule is more useful than applying the same number to every room.

Official sources

Need this sorted? Get a free, fixed quote from a registered local electrician.

07977 519533Enquire online

This guide is general information about UK electrical regulations and good practice, and any prices are indicative only. For advice on your property, speak to a registered electrician.

Talk to an electrician today

Free quotations · No hidden fees · Domestic & commercial

Call nowFree quote